说明: | K4741-100? IL-17F Microplate (Item A): 96 wells (12 strips x 8 wells) coated with anti-human IL-17F.
? Wash Buffer Concentrate (20x) (Item B): 25 ml of 20x concentrated solution.
? Standards (Item C): 2 vials, recombinant human IL-17F.
? Assay Diluent C (Item L): 30 ml of diluent buffer. For Standard/Sample (serum/plasma/cell culture medium/urine) diluent.
? Assay Diluent B (Item E): 15 ml of 5x concentrated buffer. For detection Antibody & HRP-Streptavidin diluent.
? Detection Antibody IL-17F (Item F): 2 vial of biotinylated anti-human IL-17F (each vial is enough to assay half microplate).
? HRP-Streptavidin Concentrate (Item G): 200 μl of 200x concentrated HRP-conjugated streptavidin.
? TMB One-Step Substrate Reagent (Item H): 12 ml of 3,3’,5,5’tetramethylbenzidine (TMB) in buffered solution.
? Stop Solution (Item I): 8 ml of 0.2 M sulfuric acid.
? Serum & plasma
? Cell culture supernatants
? Urine
IL-17F (human) ELISA Kit: Colorimetric Assay for Quantitative Determination of Human IL-17F in Serum, Plasma, Urine & Cell culture supernatants. Detection Limit: less than 20 pg/ml. 100 assays.BioVision’s Human IL-17F ELISA (Enzyme-Linked Immunosorbent Assay) kit is an in vitro enzyme-linked immunosorbent assay for the quantitative measurement of human IL-17F. This assay employs an antibody specific for human IL-17F coated on a 96-well plate. Standards and samples are pipetted into the wells and IL-17F present in a sample is bound to the wells by the immobilized antibody. The wells are washed and biotinylated anti-human IL-17F antibody is added. After washing away unbound biotinylated antibody, HRP-conjugated streptavidin is pipetted to the wells. The wells are again washed, a TMB substrate solution is added to the wells and color develops in proportion to the amount of IL-17F bound. The Stop Solution changes the color from blue to yellow, and the intensity of the color is measured at 450 nm. The minimum detectable dose of IL-17F is typically less than 20 pg/ml. The intra-Assay reproducibility is CV<10% & inter-Assay is CV<12%. This ELISA kit shows no cross-reactivity with any of the cytokines tested (e.g., human Angiogenin, BDNF, BLC, ENA-78, FGF-4, IL-1alpha, IL-1β, IL-2, IL-3, IL-4, IL-5, IL-6, IL-7, IL-8, IL-9, IL-10, IL-11, IL-12 p70, IL-12 p40, IL-13, IL-15, IL-17C, IL-309, IP-10, G-CSF, GM-CSF, IFN-γ, Leptin (OB), MCP-1, MCP-3, MDC, MIP-1alpha, MIP-1β, MIP-1, MMP-1, -2, -3, -10, PARC, RANTES, SCF, TARC, TGF-β, TIMP-1, TIMP-2, TNF-alpha, TNF-β, TPO, VEGF). |