K320-250
biovisionK320-250senescence detection kit, senescence kit, Senescence assay, Senescence assay kit, senescence measurement kit, measure senescence, detect senescence ? Species reactivity- Mammalian ? Kit size- 250 stainings ? Applications- The Senescence Detection Kit is designed to histochemically detect specific senescence marker in distinct pH in cultured cells and tissue sections.Cell culture cells, tissues
More
K202-400
biovision K202-400 Live cells ? Detection method- flow cytometry using FL1 channel for SYTOX Green dye (Ex = 488 nm; Em = 530 nm) and FL2 channel for Annexin V-Cy3 (Ex = 543 nm; Em = 570 nm). ? Species reactivity- Mammalian ? Kit size- Convenient sizes (25, 100 and 400 assays) ? Applications- Detecting apoptosis in living cells by flow cytometry or fluorescence microscopy. Cy3 shows brighter red fluorescence. Annexin V-Cy3 Apoptosis Detection Kit Plus: Simple One Step Assay to Detect Apoptotic, Necrotic & live cells within 10 min. No need to fix the cells. Detection: Flow Cytometry or fluorescence microscopy The assay is based on the observation that soon after initiating apoptosis, cells translocate the membrane phospholipid phosphatidylserine (PS) from the inner face of the plasma membrane to the cell surface. Once on the cell surface, PS can easily be detected by staining with a fluorescent conjugate of Annexin V, a protein that has a strong natural affinity for PS. The one-step staining procedure takes only 10 minutes. In addition, the assay can be directly performed on live cells, without the need of fixation. The Annexin V-Cy3 Apoptosis Detection Kit Plus includes annexin V-Cy3, SYTOX green dye, and binding buffer. The SYTOX green dye is impermeant to live cells and apoptotic cells, but stains necrotic cells with intense green fluorescence by binding to cellular nucleic acids. After staining a cell population with annexin V-Cy3 and SYTOX Green dye in the provided binding buffer, apoptotic cells show red fluorescence, dead cells show green fluorescence and live cells show little or no fluorescence. These populations can easily be distinguished by Fluorescence microscopy using FITC and rhodamine filters or by flow cytometry using the FL1 channel (Ex. 488 nm/Em. 530 nm) for SYTOX Green dye and FL2 channel for Annexin V-Cy3 (Ex. 543 nm/Em. 570 nm).
More
K101-100
biovision K101-100 Living cells (suspension and adherent) ? Detection method- Flow cytometry (Ex = 488 nm; Em = 530 nm) and fluorescence microscopy ? Species reactivity- Mammalian ? Kit size- Convenient sizes (25, 100, 400 assays) ? Applications- Detect early/middle stages of apoptosis; differentiate apoptosis from necrosis. Annexin V-FITC Apoptosis Detection Kit: Simple One Step Assay to Detect Apoptosis within 10 min. Can also differentiate Apoptosis vs Necrosis. Detection: Flow Cytometry or Fluorescence Microscopy Annexin V Apoptosis Detection Kit is based on the observation that soon after initiating apoptosis, cells translocate the membrane phosphatidylserine (PS) from the inner face of the plasma membrane to the cell surface. Once on the cell surface, PS can be easily detected by staining with a fluorescent conjugate of Annexin V, a protein that has a high affinity for PS. The one-step staining procedure takes only 10 minutes. Detection can be analyzed by flow cytometry or by fluorescence microscopy. The kit can differentiate apoptosis vs necrosis when performing both Annexin V-FITC and PI staining.
More
K101-25
biovision K101-25 Living cells (suspension and adherent) ? Detection method- Flow cytometry (Ex = 488 nm; Em = 530 nm) and fluorescence microscopy ? Species reactivity- Mammalian ? Kit size- Convenient sizes (25, 100, 400 assays) ? Applications- Detect early/middle stages of apoptosis; differentiate apoptosis from necrosis. Annexin V-FITC Apoptosis Detection Kit: Simple One Step Assay to Detect Apoptosis within 10 min. Can also differentiate Apoptosis vs Necrosis. Detection: Flow Cytometry or Fluorescence Microscopy Annexin V Apoptosis Detection Kit is based on the observation that soon after initiating apoptosis, cells translocate the membrane phosphatidylserine (PS) from the inner face of the plasma membrane to the cell surface. Once on the cell surface, PS can be easily detected by staining with a fluorescent conjugate of Annexin V, a protein that has a high affinity for PS. The one-step staining procedure takes only 10 minutes. Detection can be analyzed by flow cytometry or by fluorescence microscopy. The kit can differentiate apoptosis vs necrosis when performing both Annexin V-FITC and PI staining.
More
K101-400
biovision K101-400 Living cells (suspension and adherent) ? Detection method- Flow cytometry (Ex = 488 nm; Em = 530 nm) and fluorescence microscopy ? Species reactivity- Mammalian ? Kit size- Convenient sizes (25, 100, 400 assays) ? Applications- Detect early/middle stages of apoptosis; differentiate apoptosis from necrosis. Annexin V-FITC Apoptosis Detection Kit: Simple One Step Assay to Detect Apoptosis within 10 min. Can also differentiate Apoptosis vs Necrosis. Detection: Flow Cytometry or Fluorescence Microscopy Annexin V Apoptosis Detection Kit is based on the observation that soon after initiating apoptosis, cells translocate the membrane phosphatidylserine (PS) from the inner face of the plasma membrane to the cell surface. Once on the cell surface, PS can be easily detected by staining with a fluorescent conjugate of Annexin V, a protein that has a high affinity for PS. The one-step staining procedure takes only 10 minutes. Detection can be analyzed by flow cytometry or by fluorescence microscopy. The kit can differentiate apoptosis vs necrosis when performing both Annexin V-FITC and PI staining.
More
K201-100
biovision K201-100 Live cells ? Detection method- Flow cytometry (Ex = 488 nm; Em = 530 nm). ? Species reactivity- Mammalian ? Kit size- Convenient sizes (25, 100 and 400 assays) ? Applications- Annexin V-FITC kit includes Annexin V-FITC for detecting apoptosis and also propidium iodide (PI) for detecting necrosis. Annexin V-FITC Apoptosis Detection Kit Plus: Simple One Step Assay to Detect Apoptotic, Necrotic & live cells within 10 min. No need to fix the cells. Detection: Flow Cytometry The Annexin V-FITC Apoptosis Detection Kit Plus is based on the observation that soon after initiating apoptosis, most cell types translocate the membrane phospholipid phosphatidylserine (PS) from the inner face of the plasma membrane to the cell surface. Once on the cell surface, PS can easily be detected by staining with a fluorescent conjugate of Annexin V, a protein that has a strong natural affinity for PS. The one-step staining procedure takes only 10 minutes. In addition, the assay can be directly performed on live cells, without the need of fixation. The Annexin V-FITC Apoptosis Detection Kit Plus includes annexin V-FITC, SYTOX green dye, and binding buffer. The SYTOX green dye is impermeant to live cells and apoptotic cells, but stains necrotic cells with intense green fluorescence by binding to cellular nucleic acids. After staining a cell population with annexin V-FITC and SYTOX Green dye in the provided binding buffer, apoptotic cells show green fluorescence, dead cells show a higher level of green fluorescence and live cells show little or no fluorescence. These populations can easily be distinguished using a flow cytometry with the 488 nm line of an argon-ion laser for excitation. Both annexin V-FITC and SYTOX Green dye emit green fluorescence that can be detected in the FL1 channel, freeing the other channels for the addition of other probes in multi-color labeling experiments.
More
K201-25
biovision K201-25 Live cells ? Detection method- Flow cytometry (Ex = 488 nm; Em = 530 nm). ? Species reactivity- Mammalian ? Kit size- Convenient sizes (25, 100 and 400 assays) ? Applications- Annexin V-FITC kit includes Annexin V-FITC for detecting apoptosis and also propidium iodide (PI) for detecting necrosis. Annexin V-FITC Apoptosis Detection Kit Plus: Simple One Step Assay to Detect Apoptotic, Necrotic & live cells within 10 min. No need to fix the cells. Detection: Flow Cytometry The Annexin V-FITC Apoptosis Detection Kit Plus is based on the observation that soon after initiating apoptosis, most cell types translocate the membrane phospholipid phosphatidylserine (PS) from the inner face of the plasma membrane to the cell surface. Once on the cell surface, PS can easily be detected by staining with a fluorescent conjugate of Annexin V, a protein that has a strong natural affinity for PS. The one-step staining procedure takes only 10 minutes. In addition, the assay can be directly performed on live cells, without the need of fixation. The Annexin V-FITC Apoptosis Detection Kit Plus includes annexin V-FITC, SYTOX green dye, and binding buffer. The SYTOX green dye is impermeant to live cells and apoptotic cells, but stains necrotic cells with intense green fluorescence by binding to cellular nucleic acids. After staining a cell population with annexin V-FITC and SYTOX Green dye in the provided binding buffer, apoptotic cells show green fluorescence, dead cells show a higher level of green fluorescence and live cells show little or no fluorescence. These populations can easily be distinguished using a flow cytometry with the 488 nm line of an argon-ion laser for excitation. Both annexin V-FITC and SYTOX Green dye emit green fluorescence that can be detected in the FL1 channel, freeing the other channels for the addition of other probes in multi-color labeling experiments.
More
K201-400
biovision K201-400 Live cells ? Detection method- Flow cytometry (Ex = 488 nm; Em = 530 nm). ? Species reactivity- Mammalian ? Kit size- Convenient sizes (25, 100 and 400 assays) ? Applications- Annexin V-FITC kit includes Annexin V-FITC for detecting apoptosis and also propidium iodide (PI) for detecting necrosis. Annexin V-FITC Apoptosis Detection Kit Plus: Simple One Step Assay to Detect Apoptotic, Necrotic & live cells within 10 min. No need to fix the cells. Detection: Flow Cytometry The Annexin V-FITC Apoptosis Detection Kit Plus is based on the observation that soon after initiating apoptosis, most cell types translocate the membrane phospholipid phosphatidylserine (PS) from the inner face of the plasma membrane to the cell surface. Once on the cell surface, PS can easily be detected by staining with a fluorescent conjugate of Annexin V, a protein that has a strong natural affinity for PS. The one-step staining procedure takes only 10 minutes. In addition, the assay can be directly performed on live cells, without the need of fixation. The Annexin V-FITC Apoptosis Detection Kit Plus includes annexin V-FITC, SYTOX green dye, and binding buffer. The SYTOX green dye is impermeant to live cells and apoptotic cells, but stains necrotic cells with intense green fluorescence by binding to cellular nucleic acids. After staining a cell population with annexin V-FITC and SYTOX Green dye in the provided binding buffer, apoptotic cells show green fluorescence, dead cells show a higher level of green fluorescence and live cells show little or no fluorescence. These populations can easily be distinguished using a flow cytometry with the 488 nm line of an argon-ion laser for excitation. Both annexin V-FITC and SYTOX Green dye emit green fluorescence that can be detected in the FL1 channel, freeing the other channels for the addition of other probes in multi-color labeling experiments.
More
K401-60
biovision K401-60 Cell cultures (adherent and suspension), parafin embedded tissue sections ? Detection method- Flow cytometry (Ex/Em = 488/520 nm for FITC, and 488/623 nm for PI) and fluorescence microscopy (FITC and rhodamine filters) ? Species reactivity- Mammalian ? Applications- The TUNEL-based assay kit provides complete components including positive and negative control cells for convenient detection of DNA fragmentation in cultured cells and tissue sections. Apo-BrdU In Situ DNA Fragmentation Assay Kit: Convenient & Reliable Assay to Detect DNA Fragmentation by Fluorescence Microscopy or Flow Cytometry. Includes both Positive and Negative Control Cells. 60 Assays. Internucleosomal DNA fragmentation is a hallmark of apoptosis in mammalian cells. BioVision’s Apo-BrdU In Situ DNA Fragmentation Assay Kit provides complete components including positive and negative control cells for conveniently detecting DNA fragmentation by fluorescence microscopy or flow cytometry. The kit utilizes Br-dUTP (bromolated deoxyuridine triphosphate nucleotides) which is more readily incorporated into DNA strand breaks than other larger ligands (e.g., fluorescein, biotin or digoxigenin). The greater incorporation gives rise to brighter signal when the Br-dUTP sites are identified by a fluorescein labeled anti-BrdU monoclonal antibody.
More
K132-7-25
biovision K132-7-25 Cell culture ? Detection method- Absorbance (400 or 405 nm ) ? Species reactivity- Mammalian ? Kit size- 7X25 assays ? Applications- Detects specific Caspases involved in apoptosis within cells Caspase-Family Colorimetric Substrate Set: Ready-to-Use Colorimetric Substrates for Assaying Activities of Caspase-1, -2, -3, -5, -6, -8 & -9 family proteases. Concentration: 4 mM. Ready-to-use colorimetric substrates for members of caspase family proteases. All substrates were provided in liquid ready-to-use form.
More
K258-30
biovisionK258-30apoptotic cell isolation kit, isolate apoptotic cell, isolate apoptotic cells, separate apoptotic cells from healthy cells, annexin V magnetic beads to separate apoptotic cells from healthy cells, Annexin V magnetic beads to separate apoptotic cells from healthy cells? Detection method- Magnetic bead bound apoptotic cells can be separated from normal cells ? Species reactivity- Mammalian ? Applications- Kit provides a simple and efficient means for isolation of apoptotic cells from normal culture using annexin V magnetic beads (MagBeads). The separated apoptotic cells and normal cells can be used in a variety of assays to study apoptotic mechanisms and pathways. The kit has also been successfully used to remove dead cells from normal culture. Cell cultures (adherent and suspension)
More
K170-50
biovisionK170-50apoptotic dna ladder isolation kit, apoptotic DNA ladder isolation kit, apoptotic DNA ladder kit, apoptotic DNA ladder, DNA laddering kit, DNA laddering? Detection method- Agarose gel electrophoresis (with Ethidium Bromide) ? Species reactivity- Mammalian ? Kit size- 50 assays ? Applications- Extraction of apoptotic DNA ladders without interference of intact genomic DNA Mammalian cell types and tissues undergoing apoptosis
More
|
|