K202-400
biovision K202-400 Live cells ? Detection method- flow cytometry using FL1 channel for SYTOX Green dye (Ex = 488 nm; Em = 530 nm) and FL2 channel for Annexin V-Cy3 (Ex = 543 nm; Em = 570 nm). ? Species reactivity- Mammalian ? Kit size- Convenient sizes (25, 100 and 400 assays) ? Applications- Detecting apoptosis in living cells by flow cytometry or fluorescence microscopy. Cy3 shows brighter red fluorescence. Annexin V-Cy3 Apoptosis Detection Kit Plus: Simple One Step Assay to Detect Apoptotic, Necrotic & live cells within 10 min. No need to fix the cells. Detection: Flow Cytometry or fluorescence microscopy The assay is based on the observation that soon after initiating apoptosis, cells translocate the membrane phospholipid phosphatidylserine (PS) from the inner face of the plasma membrane to the cell surface. Once on the cell surface, PS can easily be detected by staining with a fluorescent conjugate of Annexin V, a protein that has a strong natural affinity for PS. The one-step staining procedure takes only 10 minutes. In addition, the assay can be directly performed on live cells, without the need of fixation. The Annexin V-Cy3 Apoptosis Detection Kit Plus includes annexin V-Cy3, SYTOX green dye, and binding buffer. The SYTOX green dye is impermeant to live cells and apoptotic cells, but stains necrotic cells with intense green fluorescence by binding to cellular nucleic acids. After staining a cell population with annexin V-Cy3 and SYTOX Green dye in the provided binding buffer, apoptotic cells show red fluorescence, dead cells show green fluorescence and live cells show little or no fluorescence. These populations can easily be distinguished by Fluorescence microscopy using FITC and rhodamine filters or by flow cytometry using the FL1 channel (Ex. 488 nm/Em. 530 nm) for SYTOX Green dye and FL2 channel for Annexin V-Cy3 (Ex. 543 nm/Em. 570 nm).
More
K101-100
biovision K101-100 Living cells (suspension and adherent) ? Detection method- Flow cytometry (Ex = 488 nm; Em = 530 nm) and fluorescence microscopy ? Species reactivity- Mammalian ? Kit size- Convenient sizes (25, 100, 400 assays) ? Applications- Detect early/middle stages of apoptosis; differentiate apoptosis from necrosis. Annexin V-FITC Apoptosis Detection Kit: Simple One Step Assay to Detect Apoptosis within 10 min. Can also differentiate Apoptosis vs Necrosis. Detection: Flow Cytometry or Fluorescence Microscopy Annexin V Apoptosis Detection Kit is based on the observation that soon after initiating apoptosis, cells translocate the membrane phosphatidylserine (PS) from the inner face of the plasma membrane to the cell surface. Once on the cell surface, PS can be easily detected by staining with a fluorescent conjugate of Annexin V, a protein that has a high affinity for PS. The one-step staining procedure takes only 10 minutes. Detection can be analyzed by flow cytometry or by fluorescence microscopy. The kit can differentiate apoptosis vs necrosis when performing both Annexin V-FITC and PI staining.
More
K101-25
biovision K101-25 Living cells (suspension and adherent) ? Detection method- Flow cytometry (Ex = 488 nm; Em = 530 nm) and fluorescence microscopy ? Species reactivity- Mammalian ? Kit size- Convenient sizes (25, 100, 400 assays) ? Applications- Detect early/middle stages of apoptosis; differentiate apoptosis from necrosis. Annexin V-FITC Apoptosis Detection Kit: Simple One Step Assay to Detect Apoptosis within 10 min. Can also differentiate Apoptosis vs Necrosis. Detection: Flow Cytometry or Fluorescence Microscopy Annexin V Apoptosis Detection Kit is based on the observation that soon after initiating apoptosis, cells translocate the membrane phosphatidylserine (PS) from the inner face of the plasma membrane to the cell surface. Once on the cell surface, PS can be easily detected by staining with a fluorescent conjugate of Annexin V, a protein that has a high affinity for PS. The one-step staining procedure takes only 10 minutes. Detection can be analyzed by flow cytometry or by fluorescence microscopy. The kit can differentiate apoptosis vs necrosis when performing both Annexin V-FITC and PI staining.
More
K101-400
biovision K101-400 Living cells (suspension and adherent) ? Detection method- Flow cytometry (Ex = 488 nm; Em = 530 nm) and fluorescence microscopy ? Species reactivity- Mammalian ? Kit size- Convenient sizes (25, 100, 400 assays) ? Applications- Detect early/middle stages of apoptosis; differentiate apoptosis from necrosis. Annexin V-FITC Apoptosis Detection Kit: Simple One Step Assay to Detect Apoptosis within 10 min. Can also differentiate Apoptosis vs Necrosis. Detection: Flow Cytometry or Fluorescence Microscopy Annexin V Apoptosis Detection Kit is based on the observation that soon after initiating apoptosis, cells translocate the membrane phosphatidylserine (PS) from the inner face of the plasma membrane to the cell surface. Once on the cell surface, PS can be easily detected by staining with a fluorescent conjugate of Annexin V, a protein that has a high affinity for PS. The one-step staining procedure takes only 10 minutes. Detection can be analyzed by flow cytometry or by fluorescence microscopy. The kit can differentiate apoptosis vs necrosis when performing both Annexin V-FITC and PI staining.
More
K201-100
biovision K201-100 Live cells ? Detection method- Flow cytometry (Ex = 488 nm; Em = 530 nm). ? Species reactivity- Mammalian ? Kit size- Convenient sizes (25, 100 and 400 assays) ? Applications- Annexin V-FITC kit includes Annexin V-FITC for detecting apoptosis and also propidium iodide (PI) for detecting necrosis. Annexin V-FITC Apoptosis Detection Kit Plus: Simple One Step Assay to Detect Apoptotic, Necrotic & live cells within 10 min. No need to fix the cells. Detection: Flow Cytometry The Annexin V-FITC Apoptosis Detection Kit Plus is based on the observation that soon after initiating apoptosis, most cell types translocate the membrane phospholipid phosphatidylserine (PS) from the inner face of the plasma membrane to the cell surface. Once on the cell surface, PS can easily be detected by staining with a fluorescent conjugate of Annexin V, a protein that has a strong natural affinity for PS. The one-step staining procedure takes only 10 minutes. In addition, the assay can be directly performed on live cells, without the need of fixation. The Annexin V-FITC Apoptosis Detection Kit Plus includes annexin V-FITC, SYTOX green dye, and binding buffer. The SYTOX green dye is impermeant to live cells and apoptotic cells, but stains necrotic cells with intense green fluorescence by binding to cellular nucleic acids. After staining a cell population with annexin V-FITC and SYTOX Green dye in the provided binding buffer, apoptotic cells show green fluorescence, dead cells show a higher level of green fluorescence and live cells show little or no fluorescence. These populations can easily be distinguished using a flow cytometry with the 488 nm line of an argon-ion laser for excitation. Both annexin V-FITC and SYTOX Green dye emit green fluorescence that can be detected in the FL1 channel, freeing the other channels for the addition of other probes in multi-color labeling experiments.
More
K201-25
biovision K201-25 Live cells ? Detection method- Flow cytometry (Ex = 488 nm; Em = 530 nm). ? Species reactivity- Mammalian ? Kit size- Convenient sizes (25, 100 and 400 assays) ? Applications- Annexin V-FITC kit includes Annexin V-FITC for detecting apoptosis and also propidium iodide (PI) for detecting necrosis. Annexin V-FITC Apoptosis Detection Kit Plus: Simple One Step Assay to Detect Apoptotic, Necrotic & live cells within 10 min. No need to fix the cells. Detection: Flow Cytometry The Annexin V-FITC Apoptosis Detection Kit Plus is based on the observation that soon after initiating apoptosis, most cell types translocate the membrane phospholipid phosphatidylserine (PS) from the inner face of the plasma membrane to the cell surface. Once on the cell surface, PS can easily be detected by staining with a fluorescent conjugate of Annexin V, a protein that has a strong natural affinity for PS. The one-step staining procedure takes only 10 minutes. In addition, the assay can be directly performed on live cells, without the need of fixation. The Annexin V-FITC Apoptosis Detection Kit Plus includes annexin V-FITC, SYTOX green dye, and binding buffer. The SYTOX green dye is impermeant to live cells and apoptotic cells, but stains necrotic cells with intense green fluorescence by binding to cellular nucleic acids. After staining a cell population with annexin V-FITC and SYTOX Green dye in the provided binding buffer, apoptotic cells show green fluorescence, dead cells show a higher level of green fluorescence and live cells show little or no fluorescence. These populations can easily be distinguished using a flow cytometry with the 488 nm line of an argon-ion laser for excitation. Both annexin V-FITC and SYTOX Green dye emit green fluorescence that can be detected in the FL1 channel, freeing the other channels for the addition of other probes in multi-color labeling experiments.
More
K201-400
biovision K201-400 Live cells ? Detection method- Flow cytometry (Ex = 488 nm; Em = 530 nm). ? Species reactivity- Mammalian ? Kit size- Convenient sizes (25, 100 and 400 assays) ? Applications- Annexin V-FITC kit includes Annexin V-FITC for detecting apoptosis and also propidium iodide (PI) for detecting necrosis. Annexin V-FITC Apoptosis Detection Kit Plus: Simple One Step Assay to Detect Apoptotic, Necrotic & live cells within 10 min. No need to fix the cells. Detection: Flow Cytometry The Annexin V-FITC Apoptosis Detection Kit Plus is based on the observation that soon after initiating apoptosis, most cell types translocate the membrane phospholipid phosphatidylserine (PS) from the inner face of the plasma membrane to the cell surface. Once on the cell surface, PS can easily be detected by staining with a fluorescent conjugate of Annexin V, a protein that has a strong natural affinity for PS. The one-step staining procedure takes only 10 minutes. In addition, the assay can be directly performed on live cells, without the need of fixation. The Annexin V-FITC Apoptosis Detection Kit Plus includes annexin V-FITC, SYTOX green dye, and binding buffer. The SYTOX green dye is impermeant to live cells and apoptotic cells, but stains necrotic cells with intense green fluorescence by binding to cellular nucleic acids. After staining a cell population with annexin V-FITC and SYTOX Green dye in the provided binding buffer, apoptotic cells show green fluorescence, dead cells show a higher level of green fluorescence and live cells show little or no fluorescence. These populations can easily be distinguished using a flow cytometry with the 488 nm line of an argon-ion laser for excitation. Both annexin V-FITC and SYTOX Green dye emit green fluorescence that can be detected in the FL1 channel, freeing the other channels for the addition of other probes in multi-color labeling experiments.
More
K401-60
biovision K401-60 Cell cultures (adherent and suspension), parafin embedded tissue sections ? Detection method- Flow cytometry (Ex/Em = 488/520 nm for FITC, and 488/623 nm for PI) and fluorescence microscopy (FITC and rhodamine filters) ? Species reactivity- Mammalian ? Applications- The TUNEL-based assay kit provides complete components including positive and negative control cells for convenient detection of DNA fragmentation in cultured cells and tissue sections. Apo-BrdU In Situ DNA Fragmentation Assay Kit: Convenient & Reliable Assay to Detect DNA Fragmentation by Fluorescence Microscopy or Flow Cytometry. Includes both Positive and Negative Control Cells. 60 Assays. Internucleosomal DNA fragmentation is a hallmark of apoptosis in mammalian cells. BioVision’s Apo-BrdU In Situ DNA Fragmentation Assay Kit provides complete components including positive and negative control cells for conveniently detecting DNA fragmentation by fluorescence microscopy or flow cytometry. The kit utilizes Br-dUTP (bromolated deoxyuridine triphosphate nucleotides) which is more readily incorporated into DNA strand breaks than other larger ligands (e.g., fluorescein, biotin or digoxigenin). The greater incorporation gives rise to brighter signal when the Br-dUTP sites are identified by a fluorescein labeled anti-BrdU monoclonal antibody.
More
03MR138K25
MP Biomedicals是一家全球性的生物医药公司,总部位于美国加利福尼亚州南部,成立于2994年,产品主要应用于细胞生物学、分子生物学、蛋白质组学、药物开发、样品预处理体系及固相肽合成等方面。
More
03MR138K80
MP Biomedicals是一家全球性的生物医药公司,总部位于美国加利福尼亚州南部,成立于2995年,产品主要应用于细胞生物学、分子生物学、蛋白质组学、药物开发、样品预处理体系及固相肽合成等方面。
More
03FAM23425
MP Biomedicals是一家全球性的生物医药公司,总部位于美国加利福尼亚州南部,成立于2996年,产品主要应用于细胞生物学、分子生物学、蛋白质组学、药物开发、样品预处理体系及固相肽合成等方面。
More
03FAM23480
MP Biomedicals是一家全球性的生物医药公司,总部位于美国加利福尼亚州南部,成立于2997年,产品主要应用于细胞生物学、分子生物学、蛋白质组学、药物开发、样品预处理体系及固相肽合成等方面。
More
03FAM23525
MP Biomedicals是一家全球性的生物医药公司,总部位于美国加利福尼亚州南部,成立于2998年,产品主要应用于细胞生物学、分子生物学、蛋白质组学、药物开发、样品预处理体系及固相肽合成等方面。
More
|
|