|
YMS-7626
Anti Arginine Vasopressin Arginine Vasopressin-北京博迈斯科技发展有限公司
More
PRX-MKA0013
Anti ARHGAP11A (KIAA0013) ARHGAP11A (KIAA0013)-北京博迈斯科技发展有限公司
More
PRX-MKA1424
Anti ARHGAP21 (KIAA1424) ARHGAP21 (KIAA1424)-北京博迈斯科技发展有限公司
More
PRX-MKA1501
Anti ARHGAP23 (KIAA1501) ARHGAP23 (KIAA1501)-北京博迈斯科技发展有限公司
More
K4788-100
K4788-100? BDNF Microplate (Item A) coated with anti-human BDNF, 96 wells ? Wash Buffer Concentrate (20x) (Item B) ? Standards (Item C) (recombinant human BDNF) ? Assay Diluent A (Item D) for Standard/Sample (serum/plasma) diluent (0.09% sodium azide as preservative) ? Assay Diluent B (Item E) for Standard/Sample (cell culture medium/urine) diluent. (5x concentrated) ? Detection Antibody BDNF (Item F), biotinylated anti-human BDNF (each vial enough for half plate) ? HRP-Streptavidin Concentrate (Item G), 200x concentrated ? TMB One-Step Substrate Reagent (Item H) 3,3’,5,5’-tetramethylbenzidine (TMB) in buffer solution ? Stop Solution (Item I), 0.2 M sulfuric acid ? Serum & plasma ? Cell culture supernatants ? Urine BDNF (human) ELISA Kit: Colorimetric Assay for Quantitative measurement of human BDNF in serum, plasma, urine & cell culture supernatants. Detection Range: 80 pg/ml – 16 ng/ml. 100 assays. BioVision’s Human BDNF ELISA (Enzyme-Linked Immunosorbent Assay) kit is an in vitro enzyme-linked immunosorbent assay for the quantitative measurement of human BDNF. This assay employs an antibody specific for human BDNF coated on a 96-well plate. Standards and samples are pipetted into the wells and BDNF present in a sample is bound to the wells by the immobilized antibody. The wells are washed and biotinylated anti-human BDNF antibody is added. After washing away unbound biotinylated antibody, HRP-conjugated streptavidin is pipetted to the wells. The wells are again washed, a TMB substrate solution is added to the wells and color develops in proportion to the amount of BDNF bound. The Stop Solution changes the color from blue to yellow, and the intensity of the color is measured at 450 nm. This ELISA kit shows no cross-reactivity with any of the cytokines tested (e.g., human Angiogenin, BDNF, BLC, ENA-78, FGF-4, IL-1α, IL-1β, IL-2, IL-3, IL-4, IL-5, IL-7, IL-8, IL-9, IL-10, IL-11, IL-12 p70, IL-12 p40, IL-13, IL-15, IL-309, IP-10, G-CSF,GM-CSF, IFN-γ, Leptin, MCP-1, MCP-2, MCP-3, MDC, MIP-1α, MIP-1δ, PARC, PDGF, RANTES, SCF, TARC, TGF-β, TIMP-1, TIMP-2, TNF-α,TNF-β, TPO, VEGF). The minimum detectable dose of BDNF is typically less than 80 pg/ml. Detection Range: 80 pg/ml – 16 ng/ml. The intra-Assay reproducibility is CV<10% & inter-Assay is CV<12%.
More
K4787-100
K4787-100? Beta-NGF Ab coated plate (Item A), 96 wells ? Wash Buffer Concentrate (20x) (Item B) ? Human Beta-NGF Standard (Item C) ? Assay Diluent (5x) (Item E) ? Biotinylated anti-human Beta-NGF Ab (Item F) ? HRP-Streptavidin Concentrate (800x) (Item G) ? TMB (Item H) ? Stop Solution (Item I) ? Serum & plasma (collect plasma using heparin as an anticoagulant. EDTA & citrate are not recommended. ? Cell culture supernatants ? Urine Beta-NGF (human) ELISA Kit: Colorimetric Assay for Quantitative measurement of human Beta-NGF in serum, plasma, urine & cell culture supernatants. Detection Range: 14 pg/ml – 5,000 pg/ml. 100 assays. BioVision’s Human Beta-NGF (beta-nerve growth factor) ELISA (Enzyme-Linked Immunosorbent Assay) kit is an in vitro enzyme-linked immunosorbent assay for the quantitative measurement of human Beta-NGF. This assay employs an antibody specific for human Beta-NGF coated on a 96-well plate. Standards and samples are pipetted into the wells and Beta-NGF present in a sample is bound to the wells by the immobilized antibody. The wells are washed and biotinylated anti-human Beta-NGF antibody is added. After washing away unbound biotinylated antibody, HRP-conjugated streptavidin is pipetted to the wells. The wells are again washed, a TMB substrate solution is added to the wells and color develops in proportion to the amount of Beta-NGF bound. The Stop Solution changes the color from blue to yellow, and the intensity of the color is measured at 450 nm. This ELISA kit shows no cross-reactivity with the following cytokines tested: human Angiogenin, BDNF, BLC, ENA-78, FGF- 4, IL-1α, IL-1β, IL-2, IL-3, IL-4, IL-5, IL-6, IL-7, IL-8, IL-9, IL-10, IL-11, IL-12 p70, IL-12 p40, IL-13, IL-15, IL-309, IP-10, G-CSF, GM-CSF, IFN-γ, Leptin (OB), MCP-1, MCP-3, MDC, MIP-1α, MIP-1 β, MIP-1δ, MMP-1, - 2, -3, -10, PARC, RANTES, SCF, TARC, TGF-β, TIMP-1, TIMP-2, TNF-α, TNF-β, TPO, VEGF. The minimum detectable dose of Beta-NGF is typically less than 14 pg/ml. Detection Range: 14 pg/ml – 5,000 pg/ml. The intra-Assay reproducibility is CV<10% & inter-Assay is CV<12%.
More
K4766-100
K4766-100? BLC Microplate (Item A) coated with anti-human BLC, 96 wells ? Wash Buffer Concentrate (20x) (Item B) ? Standards (Item C) (recombinant human BLC) ? Assay Diluent A (Item D) for Standard/Sample (serum/plasma) diluent (0.09% sodium azide as preservative) ? Assay Diluent B (Item E) for Standard/Sample (cell culture medium/urine) diluent. (5x concentrated) ? Detection Antibody BLC (Item F), biotinylated anti-human BLC (each vial enough for half plate) ? HRP-Streptavidin Concentrate (Item G), 200x concentrated ? TMB One-Step Substrate Reagent (Item H) 3,3’,5,5’-tetramethylbenzidine (TMB) in buffer solution ? Stop Solution (Item I), 0.2 M sulfuric acid ? Serum & plasma ? Cell culture supernatants ? Urine Human BLC/BCA-1/CXCL13 ELISA Kit: Colorimetric Assay for Quantitative Determination of human BLC/BCA-1/CXCL13 in Serum, Plasma, Urine & Cell culture supernatants. Detection Range: 1.5 pg/ml - 1000 pg/ml. 100 assays. BioVision’s Human BLC/BCA-1/CXCL13 ELISA (Enzyme-Linked Immunosorbent Assay) kit is an in vitro enzyme-linked immunosorbent assay for the quantitative measurement of human BLC. This assay employs an antibody specific for human BLC coated on a 96-well plate. Standards and samples are pipetted into the wells and BLC present in a sample is bound to the wells by the immobilized antibody. The wells are washed and biotinylated anti-human BLC antibody is added. After washing away unbound biotinylated antibody, HRP-conjugated streptavidin is pipetted to the wells. The wells are again washed, a TMB substrate solution is added to the wells and color develops in proportion to the amount of BLC bound. The Stop Solution changes the color from blue to yellow, and the intensity of the color is measured at 450 nm. This ELISA kit shows no cross-reactivity with any of the cytokines tested e.g., human Angiogenin, BDNF, ENA-78, FGF-4, IL-1α, IL-1β, IL-2, IL-3, IL-4, IL-5, IL-7, IL-8, IL-9, IL-10, IL-11, IL-12 p70, IL-12 p40, IL-13, IL-15, IL-309, IP-10, G-CSF, GM-CSF, IFN-γ, Leptin, MCP-1, MCP-2, MCP-3, MDC, MIP-1α, MIP-1β, MIP-1δ, PARC, PDGF, RANTES, SCF, TARC, TGF-β, TIMP-1, TIMP-2, TNF-α, TNF-β, TPO, VEGF. The minimum detectable dose of BLC is typically less than 1.5 pg/ml. Detection Range: 1.5 pg/ml - 1000 pg/ml. The intra-Assay reproducibility is CV<10% & inter-Assay is CV<12%.
More
K7424-100
K7424-100? Plate coated with hCG MAb ? hCG Standard ? hCG Enzyme Conjugate ? Wash Concentrate (20X) ? TMB Substrate ? Stop SolutionSerum or plasma Chorionic Gonadotropin (human) ELISA Kit: Rapid & convenient colorimetric assay for quantitative measurement of human Chorionic Gonadotropin (hCG) in serum or plasma. Sensitivity: 0.5mIU/ml. 100 assays. Human Chorionic Gonadotropin (hCG) is a 40 kD glycoprotein hormone secreted by the placenta. The serum hCG rises in early pregnancy to concentrations of 50,000-150,000 mIU/ml between the 8th and 12th weeks of gestation and decline to 20,000 mIU/ml by the 18th week where they remain for the duration of the pregnancy. The increased level of hCG in non-pregnant women or men suggest neoplsia. Thus hCG measurement is useful for the recognition and monitoring of chorionic tumors and as a tumor marker for other malignancies that produce hCG ectopically. These include testicular, pancreatic and bronchogenic pulmonary cancers. BioVision hCG ELISA Kit is a direct solid phase sandwich ELISA method. The samples and diluted anti-hCG-HRP conjugate are added to the wells coated with Mab to beta subunit. hCG in the serum binds to anti-hCG MAb on the well and the anti-hCG second antibody then binds to hCG. Unbound protein and HRP conjugate are washed off by wash buffer. Upon the addition of the substrate, the intensity of color is proportional to the concentration of hCG in the samples. A standard curve is prepared relating color intensity to the concentration of the hCG. The sensitivity of this ELISA test is 0.5mIU/ml.
More
K4764-100
K4764-100? CRP Microplate (Item A) coated with anti-Rat CRP, 96 wells ? Wash Buffer Concentrate (20x) (Item B) ? Standards (Item C) (recombinant Rat CRP) ? Assay Diluent (Item E) (5x concentrated) for Standard/Sample (serum/plasma/cell culture medium) diluent ? Detection Antibody CRP (Item F), biotinylated anti-Rat CRP (one vial enough to assay half plate) ? HRP-Streptavidin Concentrate (Item G), 500x concentrated ? TMB One-Step Substrate Reagent (Item H) 3,3’,5,5’-tetramethylbenzidine (TMB) in buffered solution ? Stop Solution (Item I), 0.2 M sulfuric acid ? Serum & plasma ? Cell culture supernatants Rat C Reactive Protein (CRP) ELISA Kit: Colorimetric Assay for Quantitative Determination of rat CRP in Serum, Plasma & Cell culture supernatants. Detection Limit: 0.2 ng/ml. 100 assays. BioVision’s Rat CRP (C Reactive Protein) ELISA (Enzyme-Linked Immunosorbent Assay) kit is an in vitro enzyme-linked immunosorbent assay for the quantitative measurement of Rat CRP. This assay employs an antibody specific for Rat CRP coated on a 96-well plate. Standards and samples are pipetted into the wells and CRP present in a sample is bound to the wells by the immobilized antibody. The wells are washed and biotinylated anti-Rat CRP antibody is added. After washing away unbound biotinylated antibody, HRP-conjugated streptavidin is pipetted to the wells. The wells are again washed, a TMB substrate solution is added to the wells and color develops in proportion to the amount of CRP bound. The Stop Solution changes the color from blue to yellow, and the intensity of the color is measured at 450 nm. This ELISA kit shows no cross-reactivity with the following cytokines tested: rat CINC-2, CINC-3, CNTF, Fractalkine, IL-1α, IL-1β, IL-4, IL-6, IL-10, GM-CSF, IFN-γ, Leptin, Lix, MCP-1, MIP-3α, β-NGF, TIMP-1, TNF-α. The minimum detectable dose of CRP is typically less than 0.2 ng/ml. Detection Range: 0.2 ng/ml – 60 ng/ml. The intra-Assay reproducibility is CV<10% & inter-Assay is CV<12%.
More
K7876-100
K7876-100? Human CYP1A2 Ab coated plate ? Human CYP1A2 standard ? Detection Reagent A ? Detection Reagent B ? Standard diluent ? Wash Buffer (30X) ? Assay diluent A ? Assay diluent B ? TMB ? Stop solution ? Plate Sealers ? Tissue or cell lysates ? Microsomes from human tissues or cellsCytochrome P450 1A2 (CYP1A2) Human ELISA Kit: Rapid & convenient colorimetric assay for quantitative measurement of human CYP1A2 in tissues, cells or microsomes. Sensitivity: 0.156 ng/ml. Detection Range: 0.156 ng/ml – 10 ng/ml. 100 assays. Cytochrome P450 1A2 (CYP1A2) is a monooxygenase anchored to the Endoplasmic reticulum membrane, its expression being highest in liver and intestinal and olfactory mucosal cells. CYP1A2 metabolizes ~10% of all drugs on the market. CYP1A2 is implicated in clinically relevant drug/drug interactions. BioVision’s human CYP1A2 ELISA Kit is based on the standard principle of a sandwich enzyme-linked immunosorbent assay. A human CYP1A2-specific antibody is coated on the 96-well plate. Standards or samples are then added to the appropriate wells with a biotin-conjugated antibody specific to CYP1A2. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each well and incubated. After TMB substrate solution is added, only those wells that contain CYP1A2, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color to form a blue product. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change from blue to yellow is measured spectrophotometrically at 450nm . The density of yellow color is proportional to the human CYP1A2 captured onto the plate. The concentration of CYP1A2 in the samples is then determined by comparing the O.D. of the samples to the standard curve. This ELISA kit shows no detectable cross-reactivity with related isoforms. Detection Range: 0.156 ng/ml – 10 ng/ml. Sensitivity: 0.156 ng/ml. Assay Precision: Intra-assay CV<10% and Inter-assay CV<12%.
More
K7875-100
K7875-100? Human CYP2C9 Ab coated plate ? Human CYP2C9 standard ? Detection Reagent A ? Detection Reagent B ? Standard diluent ? Wash Buffer (30X) ? Assay diluent A ? Assay diluent B ? TMB ? Stop solution ? Plate Sealers? Tissue or cell lysates ? Microsomes from human tissues or cellsCytochrome P450 2C9 (CYP2C9) Human ELISA Kit: Rapid & convenient colorimetric assay for quantitative measurement of human CYP2C9 in tissues, cells or microsomes. Sensitivity: 0.6 ng/ml. Detection Range: 0.625 ng/ml – 40 ng/ml. 100 assays. Cytochrome P450 2C9 (CYP2C9) is a monooxygenase anchored to the Endoplasmic reticulum membrane, its expression being in both hepatic and extrahepatic tissues. Hepatic CYP2C9 metabolizes drugs like warfarin and extraheapaendogenous compounds like Arachidonic acid, 5HT etc. CYP2C9 is implicated in clinically relevant drug/drug interactions. BioVision’s human CYP2C9 ELISA Kit is based on the standard principle of a sandwich enzyme-linked immunosorbent assay. A human CYP2C9-specific antibody is coated on the 96-well plate. Standards or samples are then added to the appropriate wells with a biotin-conjugated antibody specific to CYP2C9. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each well and incubated. After TMB substrate solution is added, only those wells that contain CYP2C9, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color to form a blue product. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change from blue to yellow is measured spectrophotometrically at 450nm . The density of yellow color is proportional to the human CYP2C9 captured onto the plate. The concentration of CYP2C9 in the samples is then determined by comparing the O.D. of the samples to the standard curve. This ELISA kit shows no detectable cross-reactivity with related isoforms. Detection Range: 0.625 ng/ml – 40 ng/ml. Sensitivity: 0.6 ng/ml. Assay Precision: Intra-assay CV<10% and Inter-assay CV<12%.
More
K7870-100
K7870-100? CYP2D6 Ab-coated plate ? Rat CYP2D6 standard Lyophilized (1 μg/vial) ? Detection Reagent A ? Detection Reagent B ? Standard diluent ? Wash Buffer (30X) ? Assay diluent A ? Assay diluent B ? TMB ? Stop solution ? Plate Sealers ? Tissue or cell lysates ? Microsomes from rat tissues or cellsCytochrome P450 2D6 (CYP2D6) rat ELISA Kit: Rapid & convenient colorimetric assay for quantitative measurement of rat CYP2D6 in tissues, cells or microsomes. Sensitivity: 1.56 ng/ml. Detection Range: 1.56 ng/ml – 100 ng/ml. 100 assays. Cytochrome P450 2D6 (CYP2D6) is a monooxygenase anchored to the Endoplasmic reticulum membrane, its expression being highest in liver and brain. CYP2D6 is responsible for metabolism of nearly 25% of all small molecule drugs commonly used by humans, particularly psychiatric drugs such as antidepressants, antipsychotics and stimulants. BioVision’s rat CYP2D6 ELISA Kit is based on the standard principle of a sandwich enzyme-linked immunosorbent assay. A CYP2D6-specific antibody is coated on the 96-well plate. Standards or samples are then added to the appropriate wells with a biotin-conjugated antibody specific to CYP2D6. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each well and incubated. After TMB substrate solution is added, only those wells that contain CYP2D6, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color to form a blue product. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change from blue to yellow is measured spectrophotometrically at 450nm . The density of yellow color is proportional to the rat CYP2D6 captured onto the plate. The concentration of CYP2D6 in the samples is then determined by comparing the O.D. of the samples to the standard curve. This ELISA kit shows no detectable cross-reactivity with related isoforms. Detection Range: 1.56 ng/ml – 100 ng/ml. Sensitivity: 1.56 ng/ml. Assay Precision: Intra-assay CV<10% and Inter-assay CV<12%.
More
|
|